How to install the D series electric fence Energizer? |
2025.06.20 |
|
Let's take a look at how to install the D series electric fence Energizer together.
Four-wire fence installation:
The fence wires of zone A corresponds to the A1, A2, A3, A4 terminals of the host from up to bottom; the same for B1~B4 of zone B.
Note: When install the four-wire fence, the A4 and A6 terminals of the zone A should be short-circuited, and the A3 and A5 terminals should be short-circuited; the B4 and B6 terminals of the zone B should be short-circuited, and the B3 and B5 terminals should be short-circuited. Short-circuit it.
Six-wire fence installation:
the fence wires of zone A corresponds to the terminals A1, A2, A3, A4, A5, A6 from up to bottom respectively; the same for B1~B6 of zone B.
Note:
-
In single-zone application, the number of the unused zones should be set to "O".
-
If the project uses the "anti-shear" alarm function, please use the "anti-shear terminal" instead of the "high-voltage insulated wire" at the end of the defense zone in the above picture. (Note: The two ends of the anti-shear terminal are not distinguished between positive and negative.)
-
The distance between the host high-voltage ground "E" and the grounding body of the arrester is not less than 10 meters.